Loading...
Please wait while we prepare your content
Please wait while we prepare your content


Professional FM-200 fire suppression system recharge with 24/7 emergency response. Licensed NJ fire contractor (P00747) serving data centers, server rooms, and critical facilities across Mercer County, Bucks County, and Ocean County.
Alarm Systems · Security Cameras · Access Control · Fire Protection · 24/7 Monitoring
FM-200 System Discharged? Call (609) 394-8800 for 24/7 recharge service
FM-200 (HFC-227ea) is a clean agent fire suppressant that protects critical assets without water damage. It's the preferred choice for data centers, server rooms, telecom facilities, and areas with sensitive electronics.
FM-200 is a colorless, odorless gas that leaves no residue. It suppresses fires in 10 seconds or less, protecting Class A, B, and C fires without damaging sensitive equipment.
Ideal for data centers, server rooms, telecom facilities, control rooms, and anywhere water damage would be catastrophic. FM-200 is safe for occupied spaces.
FM-200 is designed to reach extinguishing concentration in 10 seconds or less, which helps limit damage to sensitive equipment.
Your FM-200 system must be recharged after any discharge. Once the system activates, it cannot suppress another fire until the cylinders are refilled and the system is recommissioned.
If your FM-200 system discharged during a fire, it must be recharged to restore protection.
Human error, equipment malfunction, or testing accidents require a recharge to maintain protection.
If semi-annual NFPA 2001 inspection reveals low agent levels or cylinder issues, recharge may be required.
Professional FM-200 recharge involves more than just refilling the agent:
Every FM-200 recharge is quoted per site after a free on-site assessment. Final costs depend on system size, agent quantity, and service requirements.
Quoted per site
Server closets, small server rooms
Quoted per site
Data centers, telecom facilities
Quoted per site
Enterprise data centers, hospitals
Agent Price
Pounds of agent needed
Labor Rate
Hours on site
Hydrostatic Test
If cylinders require
Emergency Service
After-hours premium
The American Innovation and Manufacturing (AIM) Act of 2020 phases down HFC production, including FM-200. However, your existing system remains fully serviceable.
No replacement required - existing FM-200 systems can continue operating
Recycled agent available - secondary market provides ample supply for 20+ years
Stable pricing - recycled FM-200 pricing has held steady
Future-proof options - we also service Novec 1230 systems
Planning for the future? Novec 1230 (FK-5-1-12) is the next-generation clean agent with near-zero global warming potential. We install, service, and recharge Novec 1230 systems. If you're upgrading from a legacy halon system, read our complete guide to halon replacements for a full comparison of your options.
Learn about clean agent optionsProfessional, NFPA 2001 compliant service from licensed fire protection contractors
Call our 24/7 hotline. We send a licensed technician to your facility.
Inspect cylinders, valves, detection systems. Determine agent quantity and service requirements.
Refill FM-200 agent, re-lubricate components, test all systems, verify pressures.
Full system test, NFPA 2001 documentation, return to active protection status.
FM-200 recharge service for critical facilities across New Jersey and Pennsylvania
NJ Fire License P00747. Fully insured and certified to work on fire suppression systems.
System discharged? Call us day or night to schedule a recharge and restore your protection.
We service FM-200 systems from Fike, Kidde, Chemetron, Fenwal, Ansul, and others.
All service performed to NFPA 2001 standards with proper documentation and testing.
Protecting NJ & PA businesses since 1989. Deep expertise in fire suppression systems.
Based in Hamilton Township, NJ. Service throughout Mercer, Bucks, and Ocean Counties.
Serving data centers and critical facilities across New Jersey and Eastern Pennsylvania
FM-200 systems should be recharged as soon as possible after any discharge, whether from a fire event or accidental release. After discharge, the system cannot suppress another fire until recharged. Regular inspections per NFPA 2001 should occur semi-annually, but recharging is only needed after discharge.
FM-200 recharge cost depends on agent quantity, cylinder count, system complexity, and access requirements, so every recharge is quoted per site after a free on-site assessment.
Yes, FM-200 remains available for system recharges. The AIM Act phases down HFC production, but existing systems can still be recharged using recycled/reclaimed agent. The secondary market has ample supply expected to last 20+ years. You don't need to replace your FM-200 system.
Yes, our licensed technicians can recharge FM-200 systems from all major manufacturers including Fike, Kidde, Chemetron, Fenwal, Ansul, and others. We carry the equipment and expertise to service multi-manufacturer installations.
FM-200 recharging involves more than just refilling agent. The process includes valve assembly inspection, component re-lubrication (FM-200 dissolves lubricants), hydrostatic testing if required, pressure testing, leak detection, detection system verification, and full system recommissioning per NFPA 2001.
Both are clean agent fire suppressants, but FM-200 (HFC-227ea) has a higher global warming potential than Novec 1230 (FK-5-1-12). Novec 1230 is the newer, more environmentally friendly option. Both effectively suppress fires without water damage and are safe for occupied spaces.
24/7 emergency response. Licensed NJ fire contractor. NFPA 2001 compliant service.
Professional monitoring for existing fire alarm and sprinkler systems
Fire alarm installation, monitoring & code compliance
Clean agent suppression, kitchen hood systems, and sprinkler monitoring
Clean agent fire suppression for data centers, server rooms, and sensitive equipment