Loading...
Please wait while we prepare your content
Please wait while we prepare your content
Professional FM-200 fire suppression system recharge with 24/7 emergency response. Licensed NJ fire contractor (P00747) serving data centers, server rooms, and critical facilities across Mercer County, Bucks County, and Ocean County.
FM-200 System Discharged? Call (609) 394-8800 for immediate 24/7 recharge service
FM-200 (HFC-227ea) is a clean agent fire suppressant that protects critical assets without water damage. It's the preferred choice for data centers, server rooms, telecom facilities, and areas with sensitive electronics.
FM-200 is a colorless, odorless gas that leaves no residue. It suppresses fires in 10 seconds or less, protecting Class A, B, and C fires without damaging sensitive equipment.
Ideal for data centers, server rooms, telecom facilities, control rooms, and anywhere water damage would be catastrophic. FM-200 is safe for occupied spaces.
FM-200 reaches extinguishing concentration in 10 seconds or less, making it the fastest fire protection available. Minimize damage with rapid suppression.
Your FM-200 system must be recharged immediately after any discharge. Once the system activates, it cannot suppress another fire until the cylinders are refilled and the system is recommissioned.
If your FM-200 system discharged during a fire, immediate recharge is critical to restore protection.
Human error, equipment malfunction, or testing accidents require immediate recharge to maintain protection.
If semi-annual NFPA 2001 inspection reveals low agent levels or cylinder issues, recharge may be required.
Professional FM-200 recharge involves more than just refilling the agent:
Transparent pricing guidance for FM-200 recharge services. Final costs depend on system size, agent quantity, and service requirements.
$2,000 - $5,000
Server closets, small server rooms
$5,000 - $15,000
Data centers, telecom facilities
$15,000 - $50,000+
Enterprise data centers, hospitals
Agent Price
$30-70 per pound
Labor Rate
$100-250 per hour
Hydrostatic Test
If cylinders require
Emergency Service
After-hours premium
The American Innovation and Manufacturing (AIM) Act of 2020 phases down HFC production, including FM-200. However, your existing system remains fully serviceable.
No immediate replacement needed - existing FM-200 systems can continue operating
Recycled agent available - secondary market provides ample supply for 20+ years
Stable pricing - recycled FM-200 remains around $35/lb
Future-proof options - we also service Novec 1230 systems
Planning for the future? Novec 1230 (FK-5-1-12) is the next-generation clean agent with near-zero global warming potential. We install, service, and recharge Novec 1230 systems.
Learn about clean agent optionsProfessional, NFPA 2001 compliant service from licensed fire protection contractors
Call our 24/7 hotline. We dispatch a licensed technician to your facility immediately.
Inspect cylinders, valves, detection systems. Determine agent quantity and service requirements.
Refill FM-200 agent, re-lubricate components, test all systems, verify pressures.
Full system test, NFPA 2001 documentation, return to active protection status.
FM-200 recharge service for critical facilities across New Jersey and Pennsylvania
NJ Fire License P00747. Fully insured and certified to work on fire suppression systems.
System discharged? We respond immediately, day or night, to restore your protection.
We service FM-200 systems from Fike, Kidde, Chemetron, Fenwal, Ansul, and others.
All service performed to NFPA 2001 standards with proper documentation and testing.
Protecting NJ & PA businesses since 1985. Deep expertise in fire suppression systems.
Based in Hamilton Township, NJ. Fast response to Mercer, Bucks, and Ocean Counties.
Serving data centers and critical facilities across New Jersey and Eastern Pennsylvania
FM-200 systems should be recharged immediately after any discharge, whether from a fire event or accidental release. After discharge, the system cannot suppress another fire until recharged. Regular inspections per NFPA 2001 should occur semi-annually, but recharging is only needed after discharge.
FM-200 recharge costs typically range from $5,000 for small systems to $50,000+ for large data center systems. The agent itself costs $30-70 per pound, with labor rates of $100-250 per hour. Final pricing depends on agent quantity, cylinder count, system complexity, and access requirements.
Yes, FM-200 remains available for system recharges. The AIM Act phases down HFC production, but existing systems can still be recharged using recycled/reclaimed agent. The secondary market has ample supply expected to last 20+ years. You don't need to replace your FM-200 system.
Yes, our licensed technicians can recharge FM-200 systems from all major manufacturers including Fike, Kidde, Chemetron, Fenwal, Ansul, and others. We carry the equipment and expertise to service multi-manufacturer installations.
FM-200 recharging involves more than just refilling agent. The process includes valve assembly inspection, component re-lubrication (FM-200 dissolves lubricants), hydrostatic testing if required, pressure testing, leak detection, detection system verification, and full system recommissioning per NFPA 2001.
Both are clean agent fire suppressants, but FM-200 (HFC-227ea) has a higher global warming potential than Novec 1230 (FK-5-1-12). Novec 1230 is the newer, more environmentally friendly option. Both effectively suppress fires without water damage and are safe for occupied spaces.
24/7 emergency response. Licensed NJ fire contractor. NFPA 2001 compliant service.
Professional monitoring for existing fire alarm and sprinkler systems
Fire alarm installation, monitoring & code compliance
Sprinkler systems, clean agent suppression, and fire suppression installation
Clean agent fire suppression for data centers, server rooms, and sensitive equipment